Table of Contents

Remove
Clean and Inspect for Reuse
Install



Remove

TOC

Remove the demand flow cooling signal line.



SMALL | MEDIUM | LARGE




Clean and Inspect for Reuse

TOC
 WARNING 

When using solvents, acids, or alkaline materials for cleaning, follow the manufacturer’s recommendations for use. Wear goggles and protective clothing to reduce the possibility of personal injury.
 CAUTION 

Wear safety goggles when using an air solvent gun to prevent possible eye injury.

Clean the inside of the signal line and the 7/16-20 UNF straight thread with an o-ring seal adapter with solvent and an air solvent gun.



SMALL | MEDIUM | LARGE
   

Inspect the signal line for cracks or other damage.



SMALL | MEDIUM | LARGE
   




Install

TOC

Install the demand flow cooling signal line. Tighten the signal line fittings.

Torque Value:  9  n.m  [80 in-lb]




SMALL | MEDIUM | LARGE
   

Make sure that the oil level in the oil pan is to the full mark.

Operate the engine until the water temperature reaches 82°C [180°F]. Check the oil pressure and check for oil leaks.



SMALL | MEDIUM | LARGE


Last Modified:  19-Sep-2011