Table of Contents

Preparatory Steps
Remove
Inspect for Reuse
Install
Finishing Steps



Preparatory Steps

TOC
 WARNING 

Coolant is toxic. Keep away from children and pets. If not reused, dispose of with local environmental regulations.
  • Drain the cooling system. Refer to Procedure 008-018 in Section 8.
  • If coolant dam pressure tester, Part Number AFT-2000, is used to draw a vacuum on the cooling system, it is not necessary to drain the cooling system.


SMALL | MEDIUM | LARGE




Remove

TOC

Remove the retaining capscrew and washer.



SMALL | MEDIUM | LARGE
   

Remove the coolant filter valve and the o-ring.



SMALL | MEDIUM | LARGE
   




Inspect for Reuse

TOC

Clean the filter head and the coolant filter valve with a fiber brush and solvent.



SMALL | MEDIUM | LARGE
   

Inspect the filter head and the coolant filter valve for cracks, pitting, corrosion, or other damage. Replace if damage is found.



SMALL | MEDIUM | LARGE
   




Install

TOC

Install a new o-ring onto the coolant filter valve.



SMALL | MEDIUM | LARGE
   

Lubricate the o-ring and valve with anti-seize lubricant, Part Number 3824397, and install the coolant filter valve into the filter head.

Install the retaining capscrew and washer.

Torque Value:  20  n.m  [15 ft-lb]

Turn the valve to the "ON" position.

The valve is in the "ON" position when the valve is in the vertical position.







SMALL | MEDIUM | LARGE
   




Finishing Steps

TOC




SMALL | MEDIUM | LARGE


Last Modified:  24-Oct-2011
Feedback / Help