Table of Contents

Measure



Measure

TOC

Install a vacuum gauge or water manometer in the intake air piping.

NOTE: The gauge adapter must be installed at a 90 degree angle to the air flow in a straight section of pipe, 127 mm [5.0 in], before the turbocharger compressor inlet.





SMALL | MEDIUM | LARGE

Operate the engine at full throttle and maximum horsepower RPM with maximum load.

Record the reading on the gauge or manometer.

NOTE: Restriction must not exceed 635 mm H20 [25.0 in H20].

 
SMALL | MEDIUM | LARGE
   

If the restriction exceeds specifications, replace or clean the air filter element. Refer to the OEM service manual.



SMALL | MEDIUM | LARGE
   

Inspect the intake air piping for damage. Check for collapsed and dented piping or elbows and loose connections. Refer to the OEM service manual.





SMALL | MEDIUM | LARGE
   

Remove the test equipment.



SMALL | MEDIUM | LARGE


Last Modified:  27-Oct-2011