Table of Contents

Specifications



Specifications

TOC

Minimum Recommended Battery Capacity (Automotive and Industrial)

Battery Capacity
 Ambient Temperatures
 -18°C [0°F]0°C [32°F]
System VoltageCold Cranking AmperesReserve Capacity(1) AmperesCold Cranking AmperesReserve Capacity(1) Amperes
12 VDC18006401280480
24 VDC(2)900320640240
(1) The number of plates within a given battery size determines reserve capacity. Reserve capacity determines the length of time which sustained cranking can occur.
(2) CCA ratings are based on two 12 VDC batteries in series.

A minimum of 6 VDC at the 3-pin power connector is required to power up the ECM on CELECT™ Plus engines.

Specific Gravity at 27°C [80°F]State of Charge
1.260 to 1.280100%
1.230 to 1.25075%
1.200 to 1.22050%
1.170 to 1.19025%
1.110 to 1.130Discharged

Maximum Resistance of Starting Motor Circuit:

  • 12-VDC starting motor (ohms) 0.00075
  • 24-VDC starting motor (ohms) 0.002

Cable resistances can be obtained in accompanying battery cable resistance chart. If the frame is in ground circuit, the frame length must be considered cable of the same size as that used in the balance of the system.

ItemResistance Ohms
Connection0.00001
Additional Contacter (series-parallel switch, relays, etc.)0.00020
 
SMALL | MEDIUM | LARGE

Battery Cable Sizes - American Wire Gauge (maximum length in cranking motor circuit)

12 VDC

Number 003.7 M [12 ft]
Number 0004.9 M [16 ft]
Number 0000 or Two Number 0(1)6.1 M [20 ft]
Two Number 007.6 M [25 ft]

Battery Cable Sizes - American Wire Gauge (maximum length in cranking motor circuit)

12 VDC High-Output

Number 002.1 M [7 ft]
Number 0002.7 M [9 ft]
Number 0000 or Two Number 0(1)3.7 M [12 ft]
Two Number 004.3 M [14 ft]

Battery Cable Sizes - American Wire Gauge (maximum length in cranking motor circuit)

24 to 32 VDC

Number 006.1 M [20 ft]
Number 0008.2 M [27 ft]
Number 0000 or Two Number 0(1)10.7 M [35 ft]
Two Number 0013.7 M [45 ft]
Minimum ambient temperature without starting aid-1°C [30°F]
Minimum cranking speed without starting aid150 rpm

(1) Two strands of number 0 cable can be used in place of one number 0000 cable providing all connections are carefully made to make sure equal current flow in each parallel cable.


Last Modified:  30-May-2007